The SurgiWire Release



Insert one Keith needle through the skin into the subcutaneous plane at the dermal level to access the desired plane of dissection.
Undermine the plane of dissection from Location #1 to Location #2.
The end of the Keith needleand the wire should exit through Location #2.



Reinsert the needle tip and the wire into the dermis at Location #2.
Undermine the plane of dissection from Location #2 to Location #3.
The end of the Keith needle and the wire should exit through Location #3.



Reinsert the needle tip and the wire into the dermis at Location #3.
Undermine the plane of dissection from Location #3 to Location #1.
The end of the Keith needle and the wire should exit through Location #1.



ross the two ends (Keith needles) and gently apply an alternating oscillating motion from side to side to advance the wire loop towards Location #1 until the entire wire has been removed through Location #1.

LBL-899-7134 Rev C